The digits indicate the set value as follows:
No�
Parameter settings
P01
Working mode
P02
Temperature control
mode
P03
Maximum floor
temperature
P04
Frost protection
P05
Frost protection
setpoint
P06
Timer display option
P07
Room temp. display
option at shutdown
* It will be possible to use only a room sensor. However, this option is not recom-
mendable due to an increased risk of overheating the floor. See 4.9 Change to
Room control only
** P03 appears on relevant temperature control mode. See 4.10 Extending
Maximum floor temperature limitations to 45°C
4�3

Advanced Programmable Timer

The Advanced Programmable Timer mode enables the set-
ting of a timer-controlled program for automatic comfort
10
Danfoss ECtemp Next Plus
Settings range
01: Manual
02: Advanced Program-
mable Timer
01: Room and floor temp;
02: Only floor temp.;
03: Only room temp.*
20-30˚C (only for 01 in
P02)**
01: Enable; 02: Disable
5-9˚C
01: 24h; 02 12h
01: No display surrent
temp.;
02: Display current temp.
Default
02
01
35˚C
01
5˚C
01
01
Installation Guide