ELECTRICAL REQUIREMENTS
24kW
3pH
208 (197-219)
66
240 (220-240)
58
480 (360-500)
29
Details of other electrical systems available upon request.
SERVICE CONNECTIONS
Power Supply - Use wire suitable for at least 90°C.
EP
Nominal amp per line wire:
CW1 Cold Water - 3/8" (10mm) NPT for cold water to boil-
er. Cold water lines will have a maximum of 50 PSI
(3.5kg/cw2) and a minimum of 25 PSI (1.8 kg/cw2)
water pressure
CW2 Cold Water - 3/8" (10mm) NPT for cold water to con-
denser. Cold water lines will have a maximum of 50
PSI (3.5kg/cw2) and a minimum of 25 PSI (1.8 kg/
cw2) water pressure.
Drain - Pipe full 2" (50mm) NPT to flush floor drain ca-
D
pable of receiving water flowing at a maximum rate of
5 gallons (19 liters) per minute. DO NOT MAKE SOL-
ID CONNECTION TO FLOOR DRAIN.
Steam Take-off - Connection for operation of adjacent
ST
steam powered equipment.
OPERATION WILL BE BY:
Electrically powered, A.S.M.E. constructed and National Board
Registered, 15 PSI (1 kg/cm
NOTE: The only available space to supply utilities to the boiler is
the 6" (152mm) space between the floor and the cabinet base.
PVC & CPVC Pipe are not acceptable materials for drains.
CAUTION: REMOTE KETTLE OPERATION If this boiler is feed-
ing a remote kettle that will be more than 5 feet (1.5 meters)
away, consult factory before ordering.
WATER SUPPLY
Good quality water feed is the responsibility of the owner. Water
quality must be within the following general guidelines.
TDS: 40-125 ppm
Hardness: 35-100 ppm
Silica: <13 ppm
Chlorides: <25 ppm
Chloramine: <0.2 ppm
pH: 7.0 - 8.5
The best defense against poor water quality is a water treatment
system designed to meet your water quality conditions.
2AM36E & 3AM36E
36kW
42kW
3pH
3pH
100
117
87
--
44
--
) steam boiler rated at 24kW
2
Chlorine: <0.2 ppm
DIMENSIONS ARE IN INCHES [MM]
48kW
3pH
4 [102]
2.5 [64]
--
116
58
10.5
[267]
CW1
12.5
10.5
[318]
[267]
3 [76]
5 [127]
68 [1730]
3AM36E
55 [1397]
2AM26E
22
[559]
Figure 2
3
Service Connections
36 [914]
D
CW2
ST
6 [152]
ST
EP
CW1
D
CW2
33
EP
[838]
6
[152]
56
[1346]
28
[711]
6 [152]