16
en | Programming and operating the AMAX panel
Menu Items
3 ZONE
Figure 5.5: Zone Manager
2016.05 | 06 | F.01U.309.297
MANAGER
ADD/DELETE ZONES
INPUT ZONE No.
ZONE MODULE SEL.
ZONE FUNCTION
ZONE IN AREA
ZONE NAME INPUT
ZONE RFID: MANUAL
ZONE RFID:
AUTO
ZONE FUNCTION
ZONE FUNCTION No.
ZONE TYPE
FORCE ARM/BYPASS
SILENT AL./CHIME
ZONE PULSE COUNT
ZONE LOCKOUT
Parameters / Description
0-on board zone
1-keypad
zone
2-input mod. zone
3-RF all
4-RF RFGB glassb.
5-RF RFUN no magn
6-not used
00 = zone not used 01 - 16 = Area 1- 16
press* 3s for AUTO. 9 Digits
press* 3s for MANUAL. Trigger device, RFID will be entered
00-not used
01-instant
02-interior inst.
03-delay 1
04-interior del.1
05-delay 1 exit
06-inter. del 1 e
07-delay 2
08-inter. del 2
09-delay 2 exit
10-inter. del 2 e
11-follower
12-inter. followe
13-24 hour
14-key away toggl
15-key away on/of
16-key stay toggl
17-key stay on/of
18-24 hour panic
19-24 hour fire
20-24 h fire veri
21-tamper
22-bolt contact
23-external fault
24-technical al.
25-reset
26-instant report
0-disabled
1-force arm
2-bypass
3-all
0-disabled
1-silent alarm
2-chime mode
3-all
00 = disabled 01 - 09 Pulses
0-disabled
1-1 time al. lock
2-3 time al. lock
3-6 time al. lock
4-alarm duration
Quick Installation Guide
AMAX panel
Certification
Default
EN=0/2
EN=0/2
EN=0
EN=0
Bosch Sicherheitssysteme GmbH
00
3
0
0
0