en | Programming and operating the AMAX panel
Menu Items
Figure 5.2: Communications and Reporting Manager (continued)
2016.05 | 06 | F.01U.309.297
REPORT SETTING
ZONE RESTORE REP.
AWAY ARM/DI REPORT
STAY ARM/DI REPORT
AC FAULT REP. REC.
AC FAULT REP. DOME
SYSTEM STATUS REP.
SYS REP. WITH DOME
PANIC ALARM REPORT
FIRE ALARM REPORT
MEDICAL AL. REPORT
AUTOM. TEST REPORT
REPORT EXP. TIME:m
RPT DEL. ENTRY T:s
PANIC 2BUTTON AL
FIRE 2BUTTON AL
MEDICAL 2BUTTON AL
TEST REPORT DURAT.
TEST RPT INTERV: h
TEST REPORT: hour
TEST REPORT: min
DUAL IP
IP COMMUNICATOR
INPUT MODULE No.
IPV6 MODE
IPV4 DHCP
IPV4 ADDRESS
IPV4 SUBNET MASK
IPV4 DFLT GATEWAY
IPV4 DNS SERVER IP
IPV6 DNS SERVER IP
UPNP ENABLE
HTTP PORT NUMBER
ARP CA TIME(SEC)
WEB/USB ACCESS
WEB/USB PWD
FIRMWARE UPGRADE
MODULE HOSTNAME
UNIT DESCRIP.
TCP/UDP PORT NUM
TCP KEEP AL.(SEC)
ALT IPV4 DNS SERVR
ALT IPV6 DNS SERVR
AES ENCRYPTION
AES KEY SIZE
AES KEY STRING
CONFIG B450 ?
SIM PIN
NET. ACC. P NA
NET. P USR NA
NET. ACC. P PWD
Parameters / Description
0-no report
1-receiver 1
2-receiver 2
3-receiver 3
4-receiver 4
5-rec 1, 2, 3, 4
6-rec 1 (2,3,4 b)
7-rec 1,3 (2,4 b)
8-rec 1, 2
9-rec 1 (2 b)
10-rec 3, 4
11-rec 3 (4 b)
000 = No time limit 001 - 255 = 1 - 255 minutes
0-disabled
1-report
2-siren
3-all
0-disable
1-1 hour
2-2 hours
3-3 hours
4-4 hours
5-6 hours
6-8 hours
7-12 hours
8-24 hour
00 - 23 hours Others = Do not use real-time report
00 - 59 minutes Others = Do not use real-time report
0-1 ip module
1-2 ip modules
1,2
0-disable 1-enable
0-disable 1-enable
0.0.0.0 - 255.255.255.255
0.0.0.0 - 255.255.255.255
0.0.0.0 - 255.255.255.255
0.0.0.0 - 255.255.255.255
0000:0000:0000:0000:0000:0000:0000:0000 -
FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF
0-disable 1-enable
1-65535
1-600 (seconds)
0-disable 1-enable
4-10 ASCII printable characters in length
0-disable 1-enable
Up to sixty-three characters (letters, numbers, and dashes)
Up to twenty ASCII printable characters
1-65535
0-65 (seconds)
0.0.0.0 - 255.255.255.255
0000:0000:0000:0000:0000:0000:0000:0000 -
FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF
0-disable 1-enable
1-128 bits, 2-192 bits, 3-256 bits
32 or 48 or 64 hexadecimals characters
Only display for module 1, two options for this item:
"NO, RETURN", "YES, CONTINUE"
4-8 numbers
0-99 ASCII printable characters
0-99 ASCII printable characters
0-99 ASCII printable characters
Quick Installation Guide
AMAX panel
Certification
Default
EN=1/5/6/7
EN=1/5/6/7
EN=1/5/6/7
EN=1/5/6/7
EN=0
SSI,EN=30
EN=1-8
255.255.255.0
00080
B42V2
07700
Bosch Sicherheitssysteme GmbH
6
6
6
6
0
6
0
0
0
0
6
0
30
1
1
1
8
99
99
1
0
1
0
0
0
0
1
600
0
0
45
0
0
0
1