Configuring System Message Logging
Step 5

Configuring Module and Facility Messages Logging

You can configure the severity level and time-stamp units of messages logged by modules and facilities.
Procedure
Step 1
Step 2
Command or Action
copy running-config startup-config
Example:
switch(config)# copy
running-config startup-config
Command or Action
configure terminal
Example:
switch# configure terminal
switch(config)#
[no] logging module [severity-level]
Example:
switch(config)# logging module 3
Cisco Nexus 9000 Series NX-OS System Management Configuration Guide, Release 6.x
Configuring Module and Facility Messages Logging
Purpose
(Optional)
Copies the running configuration to the startup
configuration.
Purpose
Enters global
configuration
mode.
Enables module
log messages that
have the specified
severity level or
higher. Severity
levels range from
0 to 7:
• 0 –
emergency
• 1 – alert
• 2 – critical
• 3 – error
• 4 – warning
• 5 –
notification
• 6 –
informational
• 7 –
debugging
If the severity
level is not
37