End of operation
• Stop the flow of solution.
• Drive a few metres so that the tools rotate further for a short time. You will
avoid dripping by doing this.
Very important when using contact pads!
Brush unit button (optional):
• Press the brush unit button to raise the tool.
Pedal brush unit (optional):
• Press down the pedal and lock it in place to
raise the tool.
• Drive on a few metres further in order to pick up the remaining dirty water.
• Raise the squeegee.
Allow the suction unit to continue running until
the rest of the dirty water has been sucked into
the hose.
• Switch off the suction unit first, and then the
keyswitch.
Always drain and clean the recovery tank every time you use the
machine.
If the dirty water is allowed to stand, unpleasant smells and
deposition of the dirt will take place after a few hours.
Drain the recovery tank / solution tank
The disposal of the dirty water or the cleaning solution must be carried out in
accordance with the appropriate national regulations.
• Switch the machine off.
• Remove the hose from its holder.
Open the red or blue cap situated near the handle and lower the
end of the hose slowly to drain the solution out.
Clean the recovery tank / solution tank
• Switch the machine off.
• Open the lid until the self support locates on the tank wall.
• Remove the coarse dirt sieve (yellow), empty and clean it.
• Thoroughly rinse out the recovery tank with clean water.
• Then thoroughly rinse out the solution tank with clean water.
• Check the float is functioning correctly and that the suction filter (yellow) is
clean.
In case of damage or soiling of the float and suction filter, please refer to
Page 28.
• After draining and cleaning, screw the red and blue caps on again, and hang
the hoses from their holders again.
Clean solution tank filter
Caution:
Clogged filters reduce the flow of the cleaning solution. As a
consequence you may damage the floor coating.
• Switch the machine off.
• Once the solution tank has been drained, screw
the yellow cap from the solution tank filter and
pull it away from its holder.
• Rinse the filter under running water.
If necessary, the filter should be descaled with a 10% TASKI calcacid
solution.
The filter is lower than the tank outflow. A residual amount of
solution will flow out once the filter cap has been unscrewed.
• Refit the solution filter.
Cleaning the tools
Brush unit button (optional):
• Switch on the keyswitch.
The indicators light up briefly.
• Press the brush unit button to raise the tool.
• Switch the machine off using the keyswitch and remove the key.
Pedal brush unit (optional):
• Switch the machine off using the keyswitch and remove the key.
• Press down the pedal and lock it in place to
raise the tool.
Swingo 1250B model:
• Press the tool ejection handle briefly but firmly
with your foot.
• Clean the tools with water.
Swingo 750B model:
• Turn the tool anticlockwise away from the tool
coupling using your foot.
• Clean the tools with water.
Removing and cleaning the squeegee
• Switch the machine off.
• Pull the suction hose away from the squeegee support.
• Raise the squeegee and loosen the fixing
screws on the squeegee.
• Assemble the squeegee and tighten the fixation
screws.
• Clean the squeegee with water using a brush.
27
Need help?
Do you have a question about the swingo 1250B and is the answer not in the manual?
Questions and answers