Page 1
Before first start-up, it is essential that you read the instructions of use and the safety notes carefully. Keep the instructions of use in a good and easily accessible place so that it can be consulted at any time. ergodisc 1200 Instructions of use...
Safety instructions Due to their design and construction, TASKI machines comply with health and safety requirements of the EC guidelines and therefore carry the CE sign. Important! Switch the machine off when you: • e.g., carry out cleaning, maintenance or repair work, replace components or change to another function •...
Page 4
Regularly check the power cord for tearing or aging, and do not put the machine into operation if it is not in an flawless condition, but have it repaired by an authorised specialist! Repairs to mechanical or electrical parts of the machine must only be undertaken by JohnsonDiversey authorised customer service workshops or experts who are experienced in all relevant safety regulations.
Overview 1 Machine handle 11 Castor 2 cord strain relief 12 Motor covering 3 Power outlet max. strain 700W 13 Motor ventilation 4 Power cord 14 guide rod 5 Guide rod 15 Safety switch 6 Cable mount 16 Right lever (Motor ON/OFF) 7 pad holder 17 Display ON (plug is in power outlet) 8 Additional equipment holder...
Machine installation insert pad Check: • that there there is no point on the pad that has a thickness less than the minimum thickness of 1 cm. • that there are no foreign bodies on the pads before putting it into use (e.g., sand grains).
Page 7
t Remove the pad. t Mount or replace the pad and fasten the retainer disk to Always tighten the retainer disk properly, could cause damage to the floor when neglected. t Slowly bring machine into upright position. Start up procedure t Stand behind the machine.
Using other chemicals (e.g. chemicals containing solvents, chlorine, hydrochloric acid and hydrofluoric acid) can damage or destroy the machine. The correct dosage is recommended on the product's packaging and on the "TASKI Product Information Sheet". Application technique When using the ergodisc 1200, work with lanes.
t Connect the power plug into the wall socket. The indicators light up. t Lead the power cord with your hand. Make sure that the power cord does not touch the tool. t Hold on to the machine. t Push the safety switch and press the actuating lever at the same time.
End of operation After cleaning t Release the action lever. t Do this by pulling the plug out of the socket. t Stand behind the machine. t Pull the adjustment lever and slowly lift the guide rod until it is in the upright position. t When getting go of the adjustment lever, the guide rod snaps into place.
t Mount or replace the pad and fasten the retainer disk to Always tighten the retainer disk properly, could cause damage to the floor when neglected. t Slowly bring machine into upright position. t Wipe off the power cord with a moist rag and wrap it loosely around the machine handle and the cable mount.
t Rinse out the solution tank and the spray unit thuroughly with warm water. When the cleaning solution dries up, it could cause faults. Cleaning the machine Caution: Never clean the machine with a high water pressure or a water hose. The ingress of water into the machine might cause considerable damage to mechanical or electrical parts.
Page 13
You can find this information on the name plate of your machine, and the address of your nearest TASKI partner can be found on the last page of these operating instructions.
Malfunctions Malfunction Possible causes Troubleshooting page Connect the power plug into the wall No power supply socket. Place machine in working position Guide rod in upright position Machine does not run Call for technical service safety switch defect On the last page of these instructions of Wait a while, try again (over-current Machine was trigger will reset itself automatically)
Page 15
Machine 1200 type 50SHS/ 50SHSL Rated power 1300 Rated power(integrated socket) Frequency Power cord length Brush rpm 1200 min-1 Brush pressure 0.03 N/cm Assessed sound level LPA according to EN 60704-1 dB(A) The assessed effective acceleration value according to ISO 5349 m /s2 Splash water protection IPX0...
Disposal When placed out of service, the machine and its accessories must be disposed of according to the national regulations. Your TASKI partner can support you with this upon notification. Index Accessories ........16 Machine handle .
EU Directive. This declaration shall cease to be valid if modifications are made to the product without our approval. Product: Single disc machine Name: ergodisc 1200 Model: 50SHS/50SHSL Technical Data: 230-240V~/50Hz - 1300W Applicable EU Directives:...
Need help?
Do you have a question about the ergodisc 1200 and is the answer not in the manual?