Replacing The Lateral Moving Unit - ELNA eXpressive 970 Service Manual

Hide thumbs Also See for eXpressive 970:
Table of Contents

Advertisement

Drive cover
Hole in the needle plate

Replacing the Lateral Moving Unit

Setscrews (A)
Setscrews (B)
Connector
Connector
Needle
To remove:
1. Remove the spool stand, right cover and left cover
(see pages 4 and 5).
2. Remove the tension unit cover (see page 4).
3. Remove the three setscrews (A) and remove the
driver cover.
4. Disconnect the connectors.
5. Remove the two setscrews (B) and remove the lateral
moving unit.
To attach:
6. Attach the lateral moving unit and loosely fix it with the
two setscrews (B).
7. Push the needle bar down and rotate the handwheel
to set the index disk at "L".
8. Adjust the position of the lateral moving unit so the
needle enters into the center of the hole in the needle
plate. Tighten the two set screws (B) securely.
9. Connect the connectors and attach the parts removed
in steps 1 to 3.
40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents