6-2. MECHANISM SECTION ADJUSTMENTS
Mechanism Section Adjustments
For details of mechanism section adjustments, checks,
and replacement of mechanism parts, refer to the separate
volume "DV MECHANICAL ADJUSTMENT MANUAL I
D Mechanism ".
2-1. OPERATING WITHOUT CASSETTE
1) Refer to "2. Removal" and supply the power with the cabinet
(L) assembly removed.
However, the cabinet (L) assembly incorporates the CC
DOWN switch, so remove the FZ4800 switch block from the
cabinet (L) assembly and connect it to MR-36 board.
2) Connect the adjusting remote commander to the 26-pin multi
connector via the I/O board-1 jig (J-6082-372-A).
3) Turn on the HOLD switch of the adjusting remote commander.
4) Close the cassette compartment without the cassette to set the
loading completed state.
5) Set data: 01 to page: 1, address: 00.
6) Set data: FD to page: C, address: 52, and press the PAUSE button
of the adjusting remote commander.
7) Set data: 08 to page: D, address: 10, and press the PAUSE button
of the adjusting remote commander.
8) Turn off the HOLD switch of the adjusting remote commander.
9) While pressing the CC DOWN switch, turn the power off and
then on.
The above procedure enables the mechanism to operate without the
cassette. After checking operations, be sure to perform "Procedure
After Checking Operations".
To use the "No-Cassette Operations Mode" and "Forced Power ON
Mode" together, set the following data to page: D, address: 10.
Forced VTR power ON mode .............................................. 0A
[Procedure after checking operations]
1) Set data: 01 to page: 1, address: 00.
2) Set data: FF to page: C, address: 52, and press the PAUSE button
of the adjusting remote commander.
3) Set data: 00 to page: D, address: 10, and press the PAUSE button
of the adjusting remote commander.
4) Set data: 00 to page: 1, address: 00.
5) Disconnect the power supply of the unit.
2-2. TAPE PATH ADJUSTMENT
1. Preparations for Adjustment
1) Clean the tape running side (tape guide, capstan shaft, pinch
roller).
2) Connect the adjusting remote commander to the 26-pin multi
connector via the I/O board-1 jig (J-6082-372-A).
3) Turn on the HOLD switch of the adjusting remote commander.
4) Select page: 3, address: 3C, and set data: 07.
5) Connect the oscilloscope.
Channel 1: VC-183 board, CN6202 Pin 2 (Note 1)
External trigger: VC-183 board, CN6202 Pin 5
Connect the oscilloscope via the CPC-6 terminal board jig
(J-6082-371-A) and CPC-6 jig (J-6082-370-A).
6) Playback an alignment tape (XH2-1) for tracking.
7) Check that the oscilloscope RF waveform is flat at the entrance
and exit.
If not flat, adjust according to the separate volume
"DV MECHANICAL ADJUSTMENT MANUAL I
D Mechanism ".
8) After completing the adjustment, perform "2. Procedure after
checking operations".
Pin No.
Signal Name
1
GND
3
ENV OUT
5
J SWP
7
EQ IN
9
AGC IN
11
GND
13
TRACK ID
15
FLTD
17
TMS
19
EVF VG
Note 1: Connect Pins 1 and 2 (GND) of CN6202 with a 75 Ω
resistor.
2. Procedure after operation
1) Connect the adjusting remote commander, and turn on the HOLD
switch.
2) Select page: 3, address: 3C, and set data: 00.
3) Disconnect the power of the unit.
CH1
CH2
3.3 msec
(Trigger)
6-35
Signal Name
Pin No.
2
RF MONITOR
4
REF OUT
6
LOCK
8
VCC1
10
VCC2
12
C1ERP
14
TDOB
16
ADJ VG
18
TCK
20
TDI
Table 6-2-1.
Must be flat