Download Print this page

Sony DCR-PC7 Service Manual page 59

Digital video camera recorder
Hide thumbs Also See for DCR-PC7:

Advertisement

1. EVF Initial Data Input
Mode
VTR stop
Signal
No signal
Adjustment Page
D
Adjustment Address
D4 to DF, E8 to EF
Adjusting method:
1) Set data: 01 to page: 1, address: 00.
2) Select page D, and input the data in the following table.
Note: To write in the nonvolatile memory (EEPROM), press the
PAUSE button of the adjusting remote commander each
time the data is set.
3) Set data: 00 to page: 1, address: 00.
Address
Data
D4
00
5A
D5
D6
00
D7
90
D8
97
D9
6F
B0
DA
DB
FF
A1
DC
DD
B8
DE
93
93
DF
E8
3B
46
E9
EA
2C
DF
EB
EC
82
ED
40
A8 (NTSC), C8 (PAL)
EE
EF
4B
2. VCO Adjustment (VF-106 board)
Set the VCO freerun frequency. If deviated, the EVF screen will be
blurred.
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
1) Set data:01 to page: 1, address: 00.
2) Check the display data of page: 2, address: 11.
[If the data is "97" to "9B"]
Perform step 5) and complete this adjustment.
[If the data is "00" to "96" or "9C" to "FF"]
Perform step 3) and onwards.
3) Change the data of page: D, address: D7, and press the PAUSE
button of the adjusting remote commander.
4) Check the display data of page: 2, address: 11.
[If the data is "97" to "9B"]
Perform step 5) complete this adjustment.
[If the data is "00" to "96" or "9C" to "FF"]
Repeat steps 3) to 4).
5) Set data: 00 to page: 1, address: 00.
6-20
VTR stop/Camera standby
No signal
Display data of page: 2, address: 11 of
the adjusting remote commander
D
D7
"97" to "9B"

Advertisement