8 TECHNICAL DATA
Supply voltage range (BMV-700 / BMV-702)
Supply voltage range (BMV-700H)
Supply current (no alarm condition, backlight off)
BMV-700/BMV-702
Input voltage range auxiliary battery (BMV-702)
Input current range (with supplied shunt)
Operating temperature range
Readout resolution:
Amp hours (0 ... 100Ah)
Amp hours (100 ... 9999Ah)
Temperature
Power (-100 ... 1kW)
Power (-100 ... 1kW)
Voltage measurement accuracy
Current measurement accuracy
Potential free contact
Mode
Default mode
Rating
Dimensions:
Front panel
Body diameter
Overall depth
Net weight:
BMV
Shunt
Material
Body
Sticker
36
@Vin = 12 VDC
With relay energized
@Vin = 24 VDC
With relay energized
@Vin = 144 VDC
@Vin = 288 VDC
6.5 ... 95 VDC
60... 385 VDC
4mA
15mA
3mA
8mA
3mA
3mA
0 ... 95 VDC
±0.01V
±0.1V
±0.01A
±0.1A
±1A
±0.1Ah
±0.1%
±0.1h
±1h
±1W
±0.3%
±0.4%
Configurable
Normally open
60V/1A max.
69 x 69mm
52mm
31mm
70g
315g
ABS
Polyester