Victron energy BMV-700 Manual page 28

Battery monitor
Hide thumbs Also See for BMV-700:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
57. Time-to-go display
Must be ON to display time-to-go in the monitoring menu.
58 Starter voltage display - 702 only
Must be ON to display the auxiliary voltage in the monitoring menu.
59. Temperature display - 702 only
Must be ON to display the temperature in the monitoring menu.
60. Mid-voltage display - 702 only
Must be ON to display the mid-point voltage in the monitoring menu.
Default
ON
4.2.5 Miscellaneous
______________________________________________________________
61. Software version (read only)
The software version of the BMV
62. Restore defaults
Resets all settings to factory default by pressing SELECT.
When in normal operating mode, factory settings can be restored by pressing SETUP and SELECT
simultaneously for 3 seconds (only if setting 64, Lock setup, is off).
63. Clear history
Clears all history data by pressing SELECT.
_______________________________________________________________
64. Lock setup
When on, all settings (except this one) are locked and cannot be altered.
Default
OFF
_______________________________________________________________
65. Shunt current
When using a shunt other than the one supplied with the BMV, set to the rated current of the
shunt.
Default
500A
_______________________________________________________________
66. Shunt voltage
When using a shunt other than the one supplied with the BMV, set to the rated voltage of the
shunt.
Default
50mV
26
Range
ON/OFF
Range
OFF/ON
Range
1 – 9999A
Range
1mV– 75mV
Step size
1A
Step size
1mV

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bmv-702Bmv-700h

Table of Contents