Floor Standing Type (EXPOSED)

– All the procedure has to be verified because the cover should not open when the unit is installed.
No
Parts
1
Cabinnet
Samsung Electronics
Procedure
1) Please separate the DOOR HAND & the
DOOR BODY by pulling upwards.
2) Please unscrew the FRONT MID screw and
separate the FRONT MID by pulling down-
wards.
3) Please unscrew the GRILLE screw and sepa-
rate the GRILLE.
4) Please unscrew the FRONT MID Screw and
separate the FRONT MID.
5) Please unscrew the FRONT UPPER & the
FRONT SIDE screw and separate the FRONT
SIDE.
6) Please unscrew the FRONT UPPER screw
of the back side and separate the FRONT
UPPER.
Remark
3-89