Simultaneous Opening Of Cooling/Heating Mcu Sol Valves 1 St /2 Nd - Samsung AM007FN1DCH/AA Service Manual

System airconditioner
Hide thumbs Also See for AM007FN1DCH/AA:
Table of Contents

Advertisement

Troubleshooting
4-4-18 Simultaneous opening of Cooling/heating MCU SOL Valves 1
● During the first detection, as the system restarts after making an automatic stop to check a problem with the system
● During the second detection, please refer to the following check-up methods.
1. How to check
Are an indoor unit address,
cooling/heating position of the
MCU SOL VALVE connector correctly
Is a coil of MCU SOL VALVE
after replacing MCU SOL VALVE coils, does the
Replace MCU SOL VALVE BODY
4-52
connected?
Yes
Correctly connected?
Yes
When you restart it
same error occur again?
Yes
st
/2
nd
Check the indoor unit address,
No
cooling/heating position and make
the correct connection.
No
Check the coil connection
and fasten it again
No
Replace coils as they are defective.
Samsung Electronics