Juniper EX2300-C Hardware Manual page 94

Hide thumbs Also See for EX2300-C:
Table of Contents

Advertisement

EX2300-C and EX2300 Switches Hardware Guide
Related
Documentation
72
(13 dBm) – (0.5 dBm [HOL]) – ((5) * (0.5 dBm)) – ((2) * (0.5 dBm)) – ((2 km) *
(1.0 dBm/km)) – (1 dB [CRM]) = P
13 dBm – 0.5 dBm – 2.5 dBm – 1 dBm – 2 dBm – 1 dBm = P
P
= 6 dBm
M
The calculated power margin is greater than zero, indicating that the link has sufficient
power for transmission. Also, the power margin value does not exceed the maximum
receiver input power. Refer to the specification for your receiver to find the maximum
receiver input power.
Calculating the EX Series Switch Fiber-Optic Cable Power Budget on page 70
Understanding EX Series Switches Fiber-Optic Cable Signal Loss, Attenuation, and
Dispersion on page 106
Pluggable Transceivers Supported on EX Series Switches on page 97
M
M