Omron FQ2-S/CH Series User Manual page 60

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

*1:
Leave all signal terminals that are labeled "NC" open.
*2:
You can select whether to turn the external lighting ON (Positive) or OFF (Negative) when the signal turns ON. (The setting is called the
strobe output polarity.)
FQ2-S/CH Series User's Manual for Communications Settings (Cat. No. Z338)
Section 2 Controlling Operation and Outputting Data with a Parallel Connection
*3:
This control signal is used to turn ON external lighting when an image is taken. Connect this signal to external lighting.
*4:
This signal is output to an external device when exposure of the imaging elements is completed. If you want to move the Sensor to the
next measurement location after a measurement is completed, move the Sensor only after this signal turns ON.
Shutter Output Signal (SHTOUT)
Trigger input (TRIG)
Imaging element
shutter signal
SHTOUT
The SHTOUT signal turns ON for approximately 10 ms (fixed) when the shutter time (exposure period) elapses after
the trigger is input from an external device.
58
Wiring
ON
OFF
Trigger delay
ON
Shutter time
OFF
ON
OFF
10 ms
FQ2-S/CH User's Manual