Step 2
Teaching
Teaching means to store the region and the edge width in the region as reference data for the measurement.
[Inspect]
− [Inspection]
1
Press [Teach].
2
Place the object that is to be used as the measurement reference in front of the camera.
3
Move the rectangle to the location to be measured.
4
Press [OK].
5
Press [TEACH] on the lower right of the display.
The basic settings will be registered when teaching has been completed.
6
Press [Back] to end teaching.
Changing the measurement region: p. 227
The following data is stored as the measurement reference.
Item
Reference data
FQ2-S/CH User's Manual
− [Add item.] − [Edge Width] − [Settings] Tab Page
Parameter
Reference width
The reference edge width is set automatically.
The middle arrow is the
direction for detecting an edge.
Moves the starting point
of the measurement
region.
Drag to move
the region.
Description
Inspecting with the Edge Width Inspection Item
Moves the end point
of the measurement
region.
Changes the width
of the measurement
region.