Measurement Data That Can Be Used For External Outputs And Calculations - Omron FQ2-S/CH Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Measurement Data That Can Be Used for External Outputs and Calculations

The following values can be used as measurement data and output to external devices via the Ethernet or
used in calculations.
Expression
Data name
text string
JG
Judgment
CR[0] to CR[31] Correlation
X[0] to X[31]
Position X
Y[0] to Y[31]
Position Y
TH[0] to TH[31] Angle
SX
Reference X
SY
Reference Y
ST
Reference angle
RX
Detection coordinate X
RY
Detection coordinate Y
C
Count
4-18 Calculations and Judgments Using Inspection Item Data: p. 323
FQ2-S/CH User's Manual
Data range
−2: No judgement (not measured)
0: Judgement is OK
−1: Judgement is NG
−10:
Image error
−13: Teaching not performed error
−14: Figure not registered error
−15: Out of range error
0 to 100
-99999.9999 to 99999.9999
-99999.9999 to 99999.9999
−180 to 180
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
−180 to 180
−99,999.9999 to 99,999.9999
−99,999.9999 to 99,999.9999
This is the number of models found.
Inspecting with the Shape Search III Inspection Item
Description
This is the judgment result.
This is the correlation of the Nth model
that was found.
This is the X coordinate where the Nth
model was found.
This is the Y coordinate where the Nth
model was found.
This is the angle in which the Nth
model was found.
This is the X coordinate of the position
where the model was registered.
This is the X coordinate of the position
where the model was registered.
This is the angle when the model was
registered.
This is the X coordinate of the detection
point when the model was registered.
This is the Y coordinate of the detection
point when the model was registered.
0 to 32