Important Safety Instructions - ADC ADTEMP 421 Instruction Manual

Digital ear thermometer
Table of Contents

Advertisement

Safe and Hygienic
• No risk of broken glass or mercury ingestion.
• Completely safe for use on children.
• Cleaning of the probe can be done with an alcohol
moistened cotton tissue, making this thermometer
completely hygienic for use by the whole family.
Fever larm
10 short beeps alert the patient that he/she may have a fever.

2. Important Safety Instructions

• This instrument may be used only for the purpose described
in this booklet. The manufacturer cannot be held liable for
damage caused by incorrect application.
• Never immerse this instrument into water or other
liquids (not waterproof). For maintenance instructions
refer to the "Cleaning and Disinfecting" section.
• Do not use the instrument if you think it is damaged or
notice anything unusual
• Never open the instrument
• Earwax in the ear canal may cause a lower temperature
reading. Therefore it is important to ensure the subject's
ear canal is clean
• This instrument comprises sensitive components and must
be treated with caution. Observe the storage and operating
conditions described in the "Technical Specifications" section
• Protect it from:
• extreme temperatures
• impact and dropping
• contamination and dust
• direct sunlight
• heat and cold
• If the instrument is not going to be used for a prolonged
period the batteries should be removed
• Ensure that children do not use the instrument unsupervised;
some parts are small enough to be swallowed
4
• Error del sistema o mal funcionamiento: se
oyen 3 pitidos o bips cortos
• Alarma en caso de fiebre: se oyen 10 pitidos
o bips cortos
Memoria:
• Muestra automáticamente el valor de la
última medición
• Recuperación de 12 lecturas en el modo de
memoria
Temperatura
operativa:
10°C a 40°C (50°F a 104°F)
Temperatura de
conservación: -25°C a +55°C (-13°F a 131°F)
pagado
Aprox. 1 minuto después de haber
automático:
realizado la última medición.
Pila:
CR2032 BATTERY (X1) - 1000 mediciones
como mínimo
Tamaño:
153mm (largo) x 31 mm (ancho) x 40 mm
(alto)
Peso:
53g (con pila), 50g (sin pila)
Referencia a Cumple con la normativa ASTM E-1965
normas:
De acuerdo con el tratado del Usuario de Productos
Médicos, se recomienda realizar una inspección técnica del
termómetro cada 2 años para los usuarios profesionales.
Por favor, respete la normativa aplicable de eliminación de
residuos.
13.www.adctoday.com
En nuestra página web puede encontrar información
detallada sobre nuestros termómetros y tensiómetros,
así como sobre nuestros servicios www.adctoday.com.