Lenovo NeXtScale n1200 Installation And Service Manual page 133

Hide thumbs Also See for NeXtScale n1200:
Table of Contents

Advertisement

1. No user action needed.
• D4 : USER_RST_DEFAULT
FPC network related settings were manually cleared and reset to out-of-factory default with one of the
following actions: 1)Press hardware reset button for more than 4s. 2)Click on the "Reset to Default" button
on the FPC web 'Chassis Rear Overview' page. 3)IPMI command to FPC (ipmitool -H IP -U USERID -P
PASSWORD -I lanplus raw 0x32 0xAD).
Severity
Info
Serviceable
Automatically notify support
User Response
1. No user action needed.
• D5 : FPC_POWER_ON
This event assertion indicates that the chassis was ac cycled, FPC was rebooted, or FPC was hot-
swapped.
Severity
Info
Serviceable
Automatically notify support
User Response
1. No user action needed.
• D6 : PS_0_OUTPUT_FAIL
PSU failed to enter zero output mode after 3 re-tries.
Severity
Info
Serviceable
Automatically notify support
User Response
1. No user action needed.
• E0 : LeakSnr1_Missing
For water cool related setup only, this event indicates that drip tray is missing from fan bay#1.
Severity
Critical
Serviceable
Automatically notify support
User Response
Complete the following steps:
1. Ensure both drip trays are installed in fan bay1 and 3 of the chassis.
2. Ensure all connecting cable are plugged properly if trays are installed.
3. Replace the drip tray if the event continue to be asserted when tray is already confirmed to be
installed.
Appendix A. Fan power control (FPC) error codes