User Response
Complete the following steps:
1. Make sure all power supplies are healthy and all 6 power supplies are installed. If less number of
power supplies are installed, make sure power supply slot 1 and 2 are occupied first.
• AD : PSU_Missmatch
Power supplies of different ratings are installed in the same chassis.
Severity
Critical
Serviceable
Automatically notify support
User Response
Complete the following steps:
1. Make sure that there is no mix of different rating power supplies.
• AE : PSU_Not_Support
This error indicates at least one non-support PSU is installed.
Severity
Critical
Serviceable
Automatically notify support
User Response
Complete the following steps:
1. Make sure that all power supplies installed are Lenovo approved common form factor power
supplies supported on this type of system.
• AF : PSU_Policy_Loses
Previously configured power supply redundancy policy is lost.
Severity
Warning
Serviceable
Automatically notify support
User Response
1. Make sure that FPC USB key is installed. Check if all power supplies are installed and in healthy
condition.
2. If all good, reconfigure power supply redundancy policy when needed.
• B2 : FAN01_No_Present
Indicated fan module is missing from fan bay or not properly installed.
Severity
Critical
Serviceable
Automatically notify support
User Response
112