Online Insertion and Removal

After the SPA is properly seated, fasten the SPA in place with the captive screws, as shown in
Step 3
or
Figure
11 inch-pounds (94 to 124 N-cm). Do not overtighten.

Removing a SPA from a SIP

The system can indicate a hardware failure if you do not follow proper procedures or you remove a SPA
Caution
while the software configuration is being applied. After installing a SPA, wait at least 30 seconds before
attempting to remove it. After you remove a SPA, wait at least 15 seconds before installing another SPA
in the same subslot.
To remove a SPA from a SIP, see
If attached, remove any cables from the SPA.
Step 1
To remove the SPA from the SIP, unfasten the captive screws on the SPA, as shown in
Step 2
Figure
Grasp the handles of the SPA and pull the SPA from the SIP.
Step 3

Online Insertion and Removal

Cisco ASR 14000 Series Router SIPs and SPAs support online insertion and removal (OIR). SPAs can
be inserted or removed independently from the SIP. Online insertion and removal of a SIP with installed
SPAs is also supported.

Optical Device Installation and Maintenance

This section provides references for the installation, removal, and cleaning of optical devices.

Installing and Removing Small Form-Factor Pluggable Modules

For information on installing small form-factor pluggable (SFP) modules, see
Converter (GBIC) Module and Small Form-Factor Pluggable (SFP) GBIC Module Installation
Information and
installing an SFP module:
SPAs accept only supported optical devices. The list of supported optical devices can be found in the
"Modular Optics Compatibility" section in the product overview chapter in this guide.
Cisco ASR 14000 Series Router PLIM, SIP, and SPA Hardware Installation Guide
6-6
6-5. Tighten the locking thumbscrews on both sides of the SPA to a torque of between 8.3 and
6-5.
Specifications. The following sections of that document are particularly useful when
"Installing and Removing the GBIC Module or SFP Module"
"Installing an SFP Module"