General Specifications - S2632E; Aerial Platform; Platform; Function Speed - Snorkel S1930E Operator's Manual

Hide thumbs Also See for S1930E:
Table of Contents

Advertisement

Specifications
General Specifications – S2632E

Aerial Platform

Working height
Maximum platform height
Turning radius
Inside
Outside
Wheelbase
Ground clearance
Pothole protector raised
Pothole protector lowered
Maximum wheel load
Maximum ground pressure
Weight, EVW
Approximate
Stowed width
Stowed length
With step removed
Stowed height
Rails up
Rails down

Platform

Dimensions
Main
Extension
Total length with extension
Guardrail height
Rails up
Rails down
Toeboard height
Rated work load
Total
Extension
Maximum number of occupants

Function Speed

Platform raise
Platform lower
High Drive
Platform lower than 1.8 m (6 feet)
Low Drive
Platform higher than 1.8 m (6 feet)

Drive System

Standard
Gradeability
Maximum drive height

Drive/Lift Level Sensor Interlock

Side-to-side
Front-to-rear

Tires

Nonmarking solid rubber 38.1 cm x 12.7 cm (15" x 5")
22
9.8 m (32' 3")
8 m (26' 3")
25.4 cm (10")
234 cm (92")
1.92 m (6' 4")
6.3 cm (2.5")
1.9 cm (0.75")
1,112 kg (2,450 lbs)
430 kg/cm² (190 psi)
2,240 kg (4,938 lbs)
81.3 cm (32")
2.37 m (93.25")
2.37 m (93.25")
2.33 m (91.63")
1.93 m (76")
74 cm x 231 cm (29" x 91")
61 cm x 91.4 cm (24" x 36")
322.6 cm (127")
111.8 cm (44")
62.2 cm (24.5")
15.2 cm (6")
227 kg (500 lb)
113.3 kg (250 lb)
2 indoors only
12 to 20 seconds
20 to 26 seconds
0 to 3.2 km/h (0 to 2 mph)
0 to 0.6 km/h (0 to 0.4 mph)
Two-wheel drive
25%
8.0 m (26' 3")
1.5 degrees
4 degrees

Electrical System

Voltage
24 V DC negative chassis ground
Source
Four - 6 V 220 amp hour batteries
Fluid recommended
Charger

Hydraulic System

Maximum pressure
Reservoir capacity
System capacity
Maximum operating temperature
Hydraulic fluid recommended
Above -13°C (10°F) ISO VG32 (Mobil DTE 10 XL32)
Below -13°C (10°F) ISO VG15 (Mobil DTE 10 XL15)

Ambient Air Temperature Operating Range

Celsius
Fahrenheit

Maximum Wind Speed

Vibration

Sound Pressure Level

At work station

Group Classification

Heavy Duty – intended life
distilled water
25 amp
20,684 kPa (3,000 psi)
25.7 l (6.8 US gal)
27.6 l (7.3 US gal)
71°C (160°F)
-18°C to 43°C
0°F to 110°F
less than 2.5 m/sec²
below 70 dB(A)
100,000 load cycles
S1930E/S1932E/S2632E – 1360417
zero

Advertisement

Table of Contents
loading

This manual is also suitable for:

S1932eS2632e

Table of Contents