Section 2
Operation Instructions
Operation Instructions
The following describes execution of operation instructions that are issued to controllers.
List of Operation Instruction Commands
Instruction Name
Initialization of controller
settings (Flash)
Save controller settings
(Flash)
Measurement execution
Key lock status setting
Clear password
Clear measurement
values
Complete INIT initializes all settings (settings of all banks and system settings).
Example: To execute Complete INIT of a 2CH controller, assign a command as follows:
MRC
30h
Commands and Responses
●
Command
MRC
"30"
2 bytes
Element
Instruction code
Related information 1
Related information 2
ZFV-C
2-10
CompoWay/F Communication Command Reference
MRC
SRC
30h
05h
30h
05h
30h
05h
30h
05h
30h
05h
30h
05h
[Related information 1]=02h
SRC
Instruction code
05h
55h
Instruction
SRC
code
information 1
"05"
2 bytes
2 bytes
Specify commands corresponding to the instruction to be executed.
Specify the channel No. of the controller targeted by the command.
Example: In the case of 2CH, specify "02."
Normally, a setting other than "0000" is not accepted.
Instruction
Related information
code
1
55h
<Machine No.>
57h
<Machine No.>
90h
<Machine No.>
CAh
<Machine No.>
CCh
<Machine No.>
CDh
<Machine No.>
Related information 1
02h
Related
Related
information 2
2 bytes
4 bytes
Description
Related information 2
Measurement method (one
shot measurement/continuous
measurement/end continuous
measurement=0/1/2)
Lock status
(0: unlocked 1: locked)
0000h
0000h
Related
information
2
0001h