Omron ZFV-C Command Reference Manual page 19

Compoway/f communication
Hide thumbs Also See for ZFV-C:
Table of Contents

Advertisement

Section 2
Writing Parameter Areas
Response
MRC
"02"
2 bytes
Element
Response code
Response code for a normal end
Response code
"0000"
Response codes when an error occurs
Response code
"1001"
"1002"
"1003"
"1100"
"1101"
"1103"
"1104"
"2203"
"2204"
"2205"
ZFV-C
2-8
CompoWay/F Communication Command Reference
SRC
Response code
"02"
2 bytes
4 bytes
Indicates controller status for the command.
Name
Normal end
Error name
Long command length
Short command length
Inconsistent number of
elements/data
Parameter error
Area type error
Start address outside of
range error
End address outside of
range error
Operating error
Operating error
Operating error
Description
Description
No errors.
Cause
Command length is too long.
Command length is too short.
Number of elements and data do not match.
Data to be written is out of specified range.
Parameter type is wrong.
Writing start address is out of range.
Writing start address specifies the sensor of the
unconnected Machine No.
Specified number of elements is other than "8001."
Setting is abnormal.
Refer to the User's Manual of the ZFV-C for setting
error conditions of thresholds and the hysteresis
width.
Operating mode of sensor is other than RUN.
Invalid command.