End codes of responses are shown below.
End code
Name
"00"
Normal end
"0F"
Command error
"10"
Parity error
"11"
Framing error
"12"
Overrun error
"13"
BCC error
"14"
Format error
"16"
Subaddress error
"18"
Frame length error
An end code is returned after receiving one complete command frame addressed to the
node.
No response is made when ETX or BCC characters are missing from the command frame.
Noise may cause response errors or no response. Be sure to retry from the host.
It may take three seconds at longest from sending a command to receiving a response. If no
response is returned, be sure to send another command after waiting for at least three seconds.
Command execution ended successfully.
The specified command could not be executed.
For details on non-execution, refer to the response code.
A parity error occurred on one of the characters during command
reception.
A framing error occurred on one of the characters during command
reception.
An overrun error occurred on one of the characters during command
reception.
An illegal BCC was received.
• This response is returned when characters other than 0 to 9 or A to
F are used in command text sections. (except during echo back
tests)
• No SID and command text exist.
Or, no command text exists.
• Either MRC or SRC is missing in the command text.
• The subaddress of the receive frame is illegal (not supported).
• No subaddress, SID, and command text exist.
• The subaddress is shorter than two characters, and no SID and
command texts exist.
The receive frame exceeds the specified (supported) number of
bytes.