Mitsubishi Electric MR-J4 Instruction Manual page 98

Servo amplifers mr-j4-_b_(-rj) melservo-j4
Hide thumbs Also See for MR-J4:
Table of Contents

Advertisement

3. SIGNALS AND WIRING
(b) MR-J4-200B(-RJ)/MR-J4-350B(-RJ)
Connector
Receptacle assembly
CNP1
06JFAT-SAXGFK-XL
CNP3
03JFAT-SAXGFK-XL
CNP2
05JFAT-SAXGDK-H5.0
(c) MR-J4-60B4(-RJ) to MR-J4-350B4(-RJ)
Connector
Receptacle assembly
CNP1
06JFAT-SAXGDK-HT10.5
CNP2
05JFAT-SAXGDK-HT7.5
CNP3
03JFAT-SAXGDK-HT10.5
MR-J4-200B(-RJ)
Servo amplifier
CNP1
CNP2
CNP3
Table 3.2 Connector and applicable wire
Applicable wire
Size
AWG 16 to 10
AWG 18 to 14
Servo amplifier
(Note)
CNP1
CNP2
CNP3
Note. A pin for preventing improper connection is inserted to N- of CNP1 connector.
Table 3.3 Connector and applicable wire
Applicable wire
Size
AWG 16 to 14
3 - 21
Stripped
length [mm]
Insulator OD
47 mm or shorter
11.5
39 mm or shorter
9
Stripped
length [mm]
Insulator OD
3.9 mm or shorter
10
MR-J4-350B(-RJ)
Servo amplifier
CNP1
CNP3
CNP2
Manufa
Open tool
cturer
J-FAT-OT-EXL
JST
Manufa
Open tool
cturer
J-FAT-OT-XL
JST

Hide quick links:

Advertisement

Table of Contents
loading