Mitsubishi Electric MR-J4 Instruction Manual page 43

Servo amplifers mr-j4-_b_(-rj) melservo-j4
Hide thumbs Also See for MR-J4:
Table of Contents

Advertisement

1. FUNCTIONS AND CONFIGURATION
(c) MR-J4-500B(-RJ)
The broken line area is the same as
MR-J4-200B(-RJ) or less.
(1)
(2)
(3)
(Note)
(4)
Side
(5)
(6)
(7)
(8)
Note. Lines for slots around the battery holder are omitted from the illustration.
POINT
The servo amplifier is shown with the front cover open. The front cover cannot
be removed.
No.
Name/Application
Control circuit terminal block (TE2)
(1)
Used to connect the control circuit power supply.
Main circuit terminal block (TE1)
(2)
Connect the input power supply.
Battery holder
(3)
Install the battery for absolute position data backup.
(4)
Rating plate
Regenerative option/power factor improving reactor
terminal block (TE3)
(5)
Used to a connect a regenerative option and a
power factor improving DC reactor.
Servo motor power supply terminal block (TE4)
(6)
Connect the servo motor.
Charge lamp
(7)
When the main circuit is charged, this will light.
While this lamp is lit, do not reconnect the cables.
Protective earth (PE) terminal
(8)
Grounding terminal
1 - 26
Detailed
explanation
Section 3.1
Section 3.3
Section
12.2
Section 1.6
Section 3.1
Section 3.3
Section 3.1
Section 3.3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents