Mitsubishi Electric MR-J4 Instruction Manual page 171

Servo amplifers mr-j4-_b_(-rj) melservo-j4
Hide thumbs Also See for MR-J4:
Table of Contents

Advertisement

5. PARAMETERS
No.
Symbol
PB45
CNHF
Command notch filter
Set the command notch filter.
Setting
digit
_ _ x x
_ x _ _
x _ _ _
Table 5.5 Command notch filter setting frequency selection
Setting
value
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
Name and function
Command notch filter setting frequency selection
Refer to table 5.5 for the relation of setting values to frequency.
Notch depth selection
Refer to table 5.6 for details.
For manufacturer setting
Frequency
Setting
[Hz]
value
Disabled
20
2250
21
1125
22
750
23
562
24
450
25
375
26
321
27
281
28
250
29
225
2A
204
2B
187
2C
173
2D
160
2E
150
2F
140
30
132
31
125
32
118
33
112
34
107
35
102
36
97
37
93
38
90
39
86
3A
83
3B
80
3C
77
3D
75
3E
72
3F
Explanation
Frequency
Setting
[Hz]
value
70
40
66
41
62
42
59
43
56
44
53
45
51
46
48
47
46
48
45
49
43
4A
41
4B
40
4C
38
4D
37
4E
36
4F
35.2
50
33.1
51
31.3
52
29.6
53
28.1
54
26.8
55
25.6
56
24.5
57
23.4
58
22.5
59
21.6
5A
20.8
5B
20.1
5C
19.4
5D
18.8
5E
18.2
5F
5 - 30
Initial
value
[unit]
Refer to the
"Name and
function" column.
Initial
value
00h
0h
0h
Frequency
[Hz]
17.6
16.5
15.6
14.8
14.1
13.4
12.8
12.2
11.7
11.3
10.8
10.4
10
9.7
9.4
9.1
8.8
8.3
7.8
7.4
7.0
6.7
6.4
6.1
5.9
5.6
5.4
5.2
5.0
4.9
4.7
4.5
Setting
range

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents