"Program" will allow an entire Program to be run
immediately, and will also allow the Program to be started
at any station (to run from that point to the end).
• Use the Program button to select the Program
(Custom Manual programs will appear after the A
through F selections).
• Turn the dial to Run, to start the Program at the
beginning. The display will show "To Manually Start
Station 01...", but this only indicates that it will start
at the beginning of the program. Each station will run
for its programmed time (including Cycle and Soak
settings), and stations with no run time in the selected
program will be skipped.
• You may change the run time for the station selected
by using the +/- buttons to set the desired run time in
h:mm:ss format. Changing the run time in this screen
will only affect the station that is currently being
displayed; it will not change other station's run times
in the manual program. Changing the run time in the
"Manual Operation" screen will not change the run
time for that station in the "Set Station Run Times"
screen, which applies to the programmed automatic
run time for that station.
• To start later in the Program (at a higher numbered
station), use the down arrow to move to the station
number, and press the +/- buttons to advance to the
desired station (or SSG) number.
• Turn the dial back to Run to start the Program at the
desired station. The Program will begin at that station
and continue until the last event, then stop.
Manually started Programs and Custom Manual programs
do not run for multiple start times. Programs started at
a higher station than their beginning station do not start
over at the beginning; they run from the designated station
and run to the end, then stop.
"Manual One Station" allows any individual station, SSG,
or P/MV to be started.

sysTem off .................................................................................

To completely stop all irrigation, including any stations
which are already running, turn the dial to the System Off
position.
Within a few seconds a large OFF will appear in the display.
Any stations which were running will be shut down, and no
new automatic irrigation will be allowed to start.
54
• Use the +/- keys to select a station. Any SSGs will
appear at the end of the station list.
• From the Station 01 position, the – button will go
immediately to the highest numbered station, or the
SSGs. The Manual One Station function is the only
way to activate P/MV outputs by themselves, without
an associated station. You can assign a run time from
1 second to 6 hours to either of the P/MV outputs for
manual watering or other purposes.
• Use the left and right arrow buttons to move between
the hours:minutes:seconds fields.
• Use the +/- buttons to set the desired run time in
h:mm:ss format.
• Turn the dial to the RUN position, and observe the
display. The station or SSG will begin irrigating within
a few seconds.
The display will always show a list of items running, why
they are running, and the remaining time for each item.
The controller cannot run automatic programs with the
dial in the Off position. However, ICR remote controls will
still operate stations manually when the dial is in OFF.