Hunter HFS flow meters may only be connected to Port A.
Clik sensors may be attached to either port.
When the flow meter is installed into the two-wire path,
the ACC must be configured to read the sensor decoder.
This will be explained in detail in the next section, Set Up
Overview.

SetuP OVerVIeW

Connect an HFS Meter to an ICD-SEN

Hold the Information button, and turn dial to Set Flow
Monitoring dial position.
Choose "Select Flow Sensor."
Change Location to ADM.

Connect a Clik Sensor to an ICD-SEN

Hold the Information button, and turn dial to Set Sensor
Operation dial position.
A separate screen will set Location for each Sensor
(1 through 4).
At each Sensor input that will be attached to ICD-SEN,
change Location to ADM.
Turn dial to Advanced Features, and select Decoder to
begin programming a Sensor Decoder.

Sen/DeC SetuP

Before continuing, determine whether the HFS or Clik
Sensors are to be connected to a ICD-SEN on the two-wire
60
path, and that the location of the HFS or Clik Sensors are
mapped to the ADM, described in the section titled, "Set
Up Overview."
This creates the special sensor input assignments for the
ICD-SEN sensor decoders. This step must be completed
so that the controller and decoder will know which type of
sensor is connected where.
• There can be up to five ICD-SEN sensor decoders in a
decoder control system. They can receive addresses 1
through 5. This does NOT take away the station output
addresses 1 through 5. Sensor decoders have their
own type of address numbers, and the controller will
know which "5" is a station, versus a sensor decoder.
• Each sensor decoder has 2 ports, A and B.
• A Hunter HFS Flow Sensor may be connected to Port
A, only.
• Any "Clik" family sensor may be connected to either
Port A, or Port B. It is also possible to have an HFS
connected to Port A and a Clik sensor connected to
Port B on the same sensor decoder.
• Turn the Dial to Advanced Features and use the arrow
keys to move down to Decoder Functions.
• Press the + button.
• Move to SEN/DEC SETUP. Press the + button.
• This screen allows for the creation of the sensor input
assignments for the ICD-SEN sensor decoders. This
step must be completed so that the controller and
decoder will know which type of sensor is connected
where.