Section 4 • Repair Procedures
800-610-4101
ActionRental.com
GROUND CONTROLS
DIP Switch Legend
(models with GREEN circuit boards)
Toggle
Description
1
Drive (option)
enabled
disabled
2
Hour meter/flashing beacon
enabled
disabled
3
Not used
4
Valve coils
DC or Bi-Fuel models
Engine models
5
Platform level
ANSI models
CE models
6
Audible alarm for Drive option
enabled
disabled
7 - 16
Not used
a
K
ON
1
2
3
4
5
6
c
a
b
c
d
e
f
4 - 32
Position
b
K
ON
7
8
1
2
3
4
5
6
e
d
DIP switch SW25
DIP switch SW25A
position 1
position 8
position 9
position 16
DIP Switch Legend
(models with BLUE circuit boards)
Toggle
Description
1
Drive (option)
Off
On
2
Hour meter/flashing beacon
On
Off
Off
3
Batteries
Off
On
4
Valve coils
Off
On
5
Platform level
On
Off
6
Audible alarm for Drive option
Off
7
Engine (if equipped)
8
Machine power
7
8
9 - 16
Not used
f
TMZ-50/30
June 2005
enabled
disabled
enabled
disabled
DC or Bi-Fuel models
Engine models
DC or Bi-Fuel models
Engine models
ANSI models
CE models
enabled
disabled
Gasoline
Diesel
DC
Bi-Fuel
Engine
Part No. 65162
REV B
Position
Off
On
On
Off
Off
On
Off
On
Off
On
On
Off
Off
On
Off
On
On
Off