Fault Code
0031
0032
0033
0034
0035
0036
0037
0038
0039
0040
0041
0042
0043
Part No. 65162
FAULT CODE CHART (AFTER SERIAL NUMBER T5002-24)
Fault
Outrigger down valve
Outrigger down coil fault
Outrigger down valve
Outrigger down coil fault
Outrigger regen coil
Outrigger regen valve
fault
Outrigger regen coil
Outrigger regen valve
fault
Left front outrigger coil
LF outrigger valve coil
fault
Left front outrigger coil
LF outrigger valve coil
fault
Right front outrigger coil
RF outrigger valve coil
fault
Right front outrigger coil
RF outrigger valve coil
fault
Left rear outrigger coil
LR outrigger valve coil
fault
Left rear outrigger coil
LR outrigger valve coil
fault
Right rear outrigger coil
RR outrigger valve coil
fault
Right rear outrigger coil
RR outrigger valve coil
fault
Pump coil fault
Pump enable coil open
Section 5 • Troubleshooting Flow Charts
Condition
Possible Cause
Coil not connected to
wire harness OR open
coil open
circuit OR faulty circuit
board
Short in wire harness
coil shorted
OR faulty circuit board
Coil not connected to
wire harness OR open
coil open
circuit OR faulty circuit
board
Short in wire harness
coil shorted
OR faulty circuit board
Coil not connected to
wire harness OR open
open
circuit OR faulty circuit
board
Short in wire harness
shorted
OR faulty circuit board
Coil not connected to
wire harness OR open
open
circuit OR faulty circuit
board
Short in wire harness
shorted
OR faulty circuit board
Coil not connected to
wire harness OR open
open
circuit OR faulty circuit
board
Short in wire harness
shorted
OR faulty circuit board
Coil not connected to
wire harness OR open
open
circuit OR faulty circuit
board
Short in wire harness
shorted
OR faulty circuit board
Coil not connected to
wire harness OR open
circuit OR faulty circuit
board
TMZ-50/30
Solution
Restore connection OR
replace circuit board
Repair faulty wiring OR
replace circuit board
Restore connection OR
replace circuit board
Repair faulty wiring OR
replace circuit board
Restore connection OR
replace circuit board
Repair faulty wiring OR
replace circuit board
Restore connection OR
replace circuit board
Repair faulty wiring OR
replace circuit board
Restore connection OR
replace circuit board
Repair faulty wiring OR
replace circuit board
Restore connection OR
replace circuit board
Repair faulty wiring OR
replace circuit board
Restore connection OR
replace circuit board
Continued on next page
5 - 5