June 2005
800-610-4101
ActionRental.com
REV B
How to
Set the DIP Switch
1 Turn the key switch to the off position and push
in the red Emergency Stop button to the off
position at both the ground and platform
controls.
2 Remove the fasteners securing the top to the
ground controls box and open the ground
control box.
3 Rotate the top of the ground control box to the
position shown in the following illustration to
correctly identify the configuration of the DIP
switch settings.
a
b
KS1
KEY
SWITCH
a
b
c
d
e
f
Part No. 65162
c
d
P1
EMERGENCY
STOP
D7
VOLTAGE
REGULATOR
SW25
SW25A
DIP SWITCH
DIP SWITCH
K
K
ON
ON
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
f
e
key switch KS1
ground control lid
CPU/display circuit board U22
Emergency Stop P1
DIP switch SW25A
DIP switch SW25
4 Locate the DIP switch on the circuit board.
Move the DIP switch settings to correspond
with the configuration of the machine options.
Refer to the DIP Switch Legend on the next
page.
Although both DIP switches have
toggles marked from 1 through 8,
the CPU recognizes them as a
single DIP switch with 16 toggles
and reads the toggles switch
positions from left (position 1) to
right (position 16).
a
K
ON
1
2
3
4
5
6
c
a
b
c
d
e
f
5 Close the lid and install the fasteners.
TMZ-50/30
Section 4 • Repair Procedures
GROUND CONTROLS
b
K
ON
7
8
1
2
3
4
5
6
e
d
DIP switch SW25
DIP switch SW25A
position 1
position 8
position 9
position 16
7
8
f
4 - 31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents