Fault Code
0086
0087
0088
0089
0090
0091
0092
Part No. 65162
FAULT CODE CHART (AFTER SERIAL NUMBER T5002-24)
Fault
Spare output fault
Spare output '0' short
Engine coil fault
Engine choke coil open
Engine coil fault
Engine choke coil short
Spare output fault
Spare output '2' open
Spare output fault
Spare output '2' short
Proportional valve coil
Proportional valve coil
fault
Proportional valve coil
Proportional valve coil
fault
Section 5 • Troubleshooting Flow Charts
Condition
Possible Cause
Short in wire harness
OR faulty circuit board
Coil not connected to
wire harness OR open
circuit OR faulty circuit
board
Short in wire harness
OR faulty circuit board
Coil not connected to
wire harness OR open
circuit OR faulty circuit
board
Short in wire harness
OR faulty circuit board
Coil not connected to
wire harness OR open
open
circuit OR faulty circuit
board
Short in wire harness
shorted
OR faulty circuit board
TMZ-50/30
Solution
Repair faulty wiring OR
replace circuit board
Restore connection OR
replace circuit board
Repair faulty wiring OR
replace circuit board
Restore connection OR
replace circuit board
Repair faulty wiring OR
replace circuit board
Restore connection OR
replace circuit board
Repair faulty wiring OR
replace circuit board