Fault Codes
Fault Code Chart
Fault Code
Programmer
Diagnostic Display
34
MISSING
CONTACTOR
MAIN CONT DNC
41
LOW BATTERY
42
OVERVOLTAGE
43
THERMAL CUTBACK
98
Condition
Machine will not drive.
Machine will not drive.
Machine will not drive.
Machine will not drive.
Machine will not drive.
Z-30/20N • Z-30/20N RJ • Z-34/22 • Z-34/22N
Possible Causes
Solution
Motor controller does
Consult Genie Product
not detect the main
Support.
contactor PR1 or brake
release relay CR5.
Main contactor PR1 or
Consult Genie Product
brake release relay
Support.
CR5 did not close OR
open in org/red wire to
PR1 and/or CR5 OR
main contactor and/or
brake release relay is
defective.
Battery supply voltage
Completely charge
to motor controller less
batteries OR check
than 32V DC.
battery cable condition
OR check for corrosion
or loose connections at
battery terminals and
motor controller.
Battery supply voltage
Be sure the battery
to motor controller
charger is
more than 55V DC OR
disconnected OR
machine is being
check for loose battery
operated with the
cables or poor
connections.
battery charger
plugged in.
Machine being
Operate machine
operated outside of
within specified
temperature range of
temperature limits OR
-13°F to 185°F / -25°C
check for debris
to 85°C OR machine
around motor
being driven under
controller preventing
excessive load OR
proper cooling of the
motor controller is not
controller OR check for
being cooled
mechanical restrictions
sufficiently.
causing excessive load
on the machine.
April 2016