Genie Z-30/20N Service Manual page 102

Hide thumbs Also See for Z-30/20N:
Table of Contents

Advertisement

April 2016
6
At the battery or coil terminals, reverse the
connections. Note and record the current
reading.
Result: Both current readings are greater than
0 mA and are different by a minimum of 20%.
The coil is good.
Result: If one or both of the current readings
are 0 mA, or if the two current readings do not
differ by a minimum of 20%, the coil and/or its
internal diode are faulty and the coil should be
replaced.
Part No. 139378
Z-30/20N • Z-30/20N RJ • Z-34/22 • Z-34/22N