April 2016
Fault Codes
Tip-over hazard. When
adjusting the raised drive speed
settings, the maximum raised
drive speed must not exceed
0.6 mph / 1Km/h or 40 feet /
45 seconds / 12.2 meters /
45 seconds. If the machine is
allowed to drive faster than
specification, the machine could
become unstable and will tip
over.
Note: Additional troubleshooting of the fault codes
may by accomplished by using the hand-held
pendant motor controller programmer (Genie part
number 128551).
Note: When using the hand-held pendant motor
controller programmer, the M1 MAX SPEED needs
to be set to 33. If needed, adjust the M1 MAX
SPEED higher or lower to achieve the maximum
raised drive speed of 0.6 mph / 1Km/h or 40 feet /
45 seconds / 12.2 meters / 45 seconds.
The controller status indicator light will flash a fault
code to aid in troubleshooting. This indicator light is
mounted on the tilt level sensor mounting bracket,
located behind the cover on the ground controls
side.
Fault codes are two digits. The controller status
indicator light will blink the first digit of a two digit
code, pause for 1 second, and then blink the
second digit. There will be a 2 second pause
between codes.
Part No. 139378
Z-30/20N • Z-30/20N RJ • Z-34/22 • Z-34/22N
For example: the indicator light blinks
4 consecutive times, pauses for 1 second, and
then blinks 1 time. That would indicate Fault Code
41.
Service Manual
Fault Codes
95