PVEO/PVEH/PVES Operating Conditions
Pilot Pressure
Storage Temp.
Operating Temp.
Oil Viscosity
Oil Cleanliness
Supply Voltage (U
)
DC
Supply Voltage (U
)
DC
Signal Voltage (U
)
S
Signal Voltage PWM (U
)
S
PWM Frequency (U
)
S
Input Impedance
Input Capacitance
Supply Voltage (U
)
DC
Signal Voltage (U
)
S
Signal Voltage PWM (U
)
S
PWM Frequency (U
)
S
Input Impedance
Input Capacitance
AN00000350xx-04 • Rev 0102 • Mar 2017
Nominal
13.5 bar [196 psi]
Minimum
10.0 bar [145 psi]
Maximum
15.0 bar [220 psi]
-50°C → 90°C [-58°F → 194°F]
Ambient
-40°C → 90°C [-40°F → 194°F]
Ambient
12 → 75 cSt [65 → 347 SUS]
Operating range
Minimum
4 cSt [39 SUS]
Maximum
460 cSt [2128 SUS]
Maximum
18/16/13 (acc. to ISO 4406)
PVEO Control Specification
Rated
12 V
DC
11 → 15 V
Range
Max. ripple
5 %
PVEM Control Specification
11 → 32 V
Rated/Range
Max. ripple
5%
Neutral
U
= 0.5 • U
S
Q: P → A
= (0.5 → 0.25) • U
U
S
Q: P → B
= (0.5 → 0.75) • U
U
S
neutral
U
= 50% DUT
S
Q: P → A
= 50% → 25% DUT
U
S
Q: P → B
= 50% → 75% DUT
U
S
Recommended
> 200 Hz
Rated
12 kΩ
Rated
100 nF
PVEA/PVEH/PVES Control Specification
11 → 32 V
Rated/Range
Max. ripple
5%
Neutral
U
= 0.5 • U
S
Q: P → A
= (0.5 → 0.25) • U
U
S
Q: P → B
= (0.5 → 0.75) • U
U
S
neutral
U
= 50% DUT
S
Q: P → A
= 50% → 25% DUT
U
S
Q: P → B
= 50% → 75% DUT
U
S
Recommended
> 1000 Hz
Rated
12 kΩ
Rated
100 nF
24 V
DC
22 → 30 V
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC