Circulation Pump; Drain Pump - AEG Favorit CE Instruction Book

Table of Contents

Advertisement

Circulation Pump

The circulation pump is driven by an asynchronous
motor with an auxiliary winding. The auxiliary winding
ist in circuit with a 3 µF (2,5 µF, UK) capacitor. A tacho
generator is used for speed control.
There are two speeds for rinsing.
2800 1/min, 1600 1/min, Power output 80 W

Drain Pump

The drain pump is driven by a synchronous motor.
Power output 23 W.
Pump rate 10l/min.
NTC-Temperate sensor
NTC-Tem peraturfühler
Tem perature sensor NTC-resistor
Temperatur/Widerstand
temperature/resistor
(nur bei vollelektron.
Geschirrspüler)
(only for fully electronic dishw asher)
Electronic
On electronic models, a micro processor controls all
components, this is done using triacs. The electronic also
memorizes all programme data.
The heating is switched by a relay on the electronic board.
Spares Operation - R.Kurzke 02/02
20 °C / 6032 Ω
25°C / 4700
25 °C / 4829 Ω
30°C / 3787
30 °C / 3891 Ω
50°C / 1695
40 °C / 2573 Ω
60°C / 1172
50 °C / 1741 Ω
65°C /
981,7
55 °C / 1444 Ω
75°C /
698,6
60 °C / 1204 Ω
65 °C / 1009 Ω
70 °C / 849 Ω
- 6 -