Circulation Pump
The circulation pump is driven by an asynchronous
motor with an auxiliary winding. The auxiliary winding
ist in circuit with a 3 µF (2,5 µF, UK) capacitor. A tacho
generator is used for speed control.
There are two speeds for rinsing.
2800 1/min, 1600 1/min, Power output 80 W
Drain Pump
The drain pump is driven by a synchronous motor.
Power output 23 W.
Pump rate 10l/min.
NTC-Temperate sensor
NTC-Tem peraturfühler
Tem perature sensor NTC-resistor
Temperatur/Widerstand
temperature/resistor
(nur bei vollelektron.
Geschirrspüler)
(only for fully electronic dishw asher)
Electronic
On electronic models, a micro processor controls all
components, this is done using triacs. The electronic also
memorizes all programme data.
The heating is switched by a relay on the electronic board.
Spares Operation - R.Kurzke 02/02
20 °C / 6032 Ω
25°C / 4700
25 °C / 4829 Ω
30°C / 3787
30 °C / 3891 Ω
50°C / 1695
40 °C / 2573 Ω
60°C / 1172
50 °C / 1741 Ω
65°C /
981,7
55 °C / 1444 Ω
75°C /
698,6
60 °C / 1204 Ω
65 °C / 1009 Ω
70 °C / 849 Ω
- 6 -
599 513 616 EN