Resetting the configuration

The Wizard IP asks for an unknown admin password
This may occur if the Wizard IP has been previously configured. If the existing
admin password cannot be discovered, then your only recourse is to perform a
factory reset.
To invoke a configuration reset by switch
1 Remove power from the Wizard IP unit.
2 At the rear of the Wizard IP, adjacent to the power input socket, click mini
switch 1 to its ON (down) position.
3 Re-apply power to the Wizard IP. On the locally connected monitor you
should see a Maintenance menu:
Wizard IP Maintenance
To upgrade unit, visit:
http://192.168.42.154
Configure Network
Reset Configuration
Put option switch 1 up to
return to normal operation.
4 Select the 'Reset configuration' option.
A warning screen will be displayed. Select the RESET option and press
Wizard IP Reset Config
WARNING: Continuing will cause
your existing configuration to
be erased.
The unit will then reset and
require re-configuring before
it can be used.
DO YOU WISH TO CONTINUE?
RESET
5 Remove power, return the mini switch 1 to its OFF position and then re-
apply power. The locally connected monitor should display the first screen of
the
initial configuration
sequence.
Cancel
The Wizard IP does not display the configuration sequence
If the Wizard IP has been previously configured it may not automatically display
the first of the setup screens. In this case you have two options, either:
• Access the Unit, Network and Serial
• Reset the configuration:
To invoke a configuration reset by main menu
1 Using the locally connected keyboard and screen, log on as the admin user.
2 Select the 'Configuration' option.
Wizard IP Configuration
Unit Configuration
Network Configuration
Modem Configuration
Reset Configuration
3 Highlight the 'Reset configuration' option and press
A warning screen will be displayed, select the RESET option and press
.
Wizard IP Reset Config
WARNING: Continuing will cause
your existing configuration to
be erased.
The unit will then reset and
require re-configuring before
it can be used.
DO YOU WISH TO CONTINUE?
RESET
4 The Wizard IP will reset and then display the first of the four
configuration
screens.
configuration screens