Black Box SAC510NA Quick Start Manual
Black Box SAC510NA Quick Start Manual

Black Box SAC510NA Quick Start Manual

Intelli-pass biometric access control

Advertisement

Quick Links

Intelli-Pass™ Quick-Start Guide
Featuring enhanced biometric security with two-
factor authentication, providing the perfect blend
of security and simplicity.
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
Customer
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Support
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Information
Web site: www.blackbox.com • E-mail: info@blackbox.com
BLACK BOX
August 2009
SAC510NA
SAC510SA
SAC500MSA
®

Advertisement

Table of Contents
loading

Summary of Contents for Black Box SAC510NA

  • Page 1 Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) Customer FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Support Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Information Web site: www.blackbox.com • E-mail: info@blackbox.com...
  • Page 2 Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks, and Intelli-Pass is a trademark, of BB Technologies, Inc. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.
  • Page 3: Fcc Statement

    FCC Statement Federal Communications Commission and Industry Canada Radio Frequency Interference Statements This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause inter ference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment.
  • Page 4 Intelli-Pass Quick Start Guide Instrucciones de Seguridad (Normas Oficiales Mexicanas Electrical Safety Statement) 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3.
  • Page 5: Table Of Contents

    Entering the Menu After Initial Setup..........................26 5. Troubleshooting ..................................27 5.1 Problem/Solution ................................27 5.2 Calling Black Box ................................27 5.3 Shipping and Packaging ..............................27 Appendix A: Head Alignment Template ............................28 Appendix B: Software Flowcharts ............................... 29...
  • Page 6: Specifications

    Intelli-Pass Quick Start Guide 1. Specifications Battery Backup Time: 8 hours Encryption: Proprietary algorithm (head-unit to controller communications) User Controls: 12-digit keypad, LCD menu Power: Input: 100–240 VAC, 50–60 Hz; Output: 18.5 VDC, 3.5 amps, 65 watts Size: Control Unit: 10.5"H x 10.3"W x 4"D (26.7 x 26.2 x 10.2 cm); Head Unit: 5.8"H x 7.5"W x 2.4"D (14.6 x 19.1 x 6 cm) 724-746-5500 | blackbox.com Page 6...
  • Page 7: Overview

    Intelli-Pass and how to set up user access to the door. 2.2 What’s Included Your package should include the following items. If anything is missing or damaged, please contact Black Box Technical Support at 724-746-5500.
  • Page 8: Head Unit Front Section

    Intelli-Pass Quick Start Guide 2.3 Head Unit Front Section Figure 2-1 shows the Intelli-Pass head unit’s front section. 2-line LCD display Fingerprint scanner area Keypad Figure 2-1. Head unit’s front section. 2.4 Head Unit Back Section Figure 2-2 illustrates the Intelli-Pass head unit’s back section. Mounting holes Cable...
  • Page 9: Control Unit

    Chapter 2: Overview 2.5 Control Unit Figure 2-3 illustrates the control unit. Figure 2-3. Control unit. Page 9...
  • Page 10: Installing The Intelli-Pass

    Intelli-Pass Quick Start Guide 3. Installing the Intelli-Pass 3.1 Installing the Head Unit 3.1.1 Front Section Locate a surface adjacent to the opening side of the door, making sure that a person can stand directly in front of the unit with- out obstruction.
  • Page 11: Connecting The Head Unit To The Control Unit

    1. Once the back plate of the head unit and the control unit are securely mounted, run a 4-pair (8-conductor) Belden 9504 cable (available from Black Box) or equivalent cable between the control unit and head unit. 2. The cable will exit the control unit via one of the push-out holes located on the bottom of the unit, running neatly along the wall and into the hole drilled through the rear of the head unit.
  • Page 12: Connecting The Power Source To The Control Unit

    Make sure that you have a power outlet near the control unit which will ONLY be used to supply power to the control unit. CAUTION: Use ONLY the power supply you received from Black Box to power the control unit (or an exact equivalent).
  • Page 13: Connecting An Electric Strike To The Control Unit

    Chapter 3: Installing the Intelli-Pass 3.5 Connecting an Electric Strike to the Control Unit 1. Fit an appropriate lock to the door. NOTE: The type of lock used determines how you wire the control unit. Figure 3-3. Linking an electric strike to the control unit. 3.5.1 Fail-Safe Locks and Magnetic Locks (12V) A fail-safe or magnetic lock has a permanent 12V supply to keep the lock closed.
  • Page 14: Fail-Secure Locks (12V)

    Intelli-Pass Quick Start Guide 3.5.2 Fail-Secure Locks (12V) A fail-secure lock requires a 12V supply to open the lock. 1. Connect the Ground Lead of the lock to the terminal labeled GND. 2. Connect the Live Lead of the lock to the terminal labeled SOL. 3.
  • Page 15: Fail-Secure Locks (24V)

    Chapter 3: Installing the Intelli-Pass 3.5.4 Fail-Secure Locks (24V) A fail-secure lock requires a 24V supply to open the lock. The Intelli-Pass controller does not supply a 24V output. To use a 24V lock, you will need a separate power supply. Wire a 24V fail-secure lock as shown in Figure 3-7. Figure 3-7.
  • Page 16: Door Sensor

    Intelli-Pass Quick Start Guide 3.7 Door Sensor The Intelli-Pass uses the door sensor contacts for the forced door and propped door features. Connect the door sensor as shown in Figure 3-9. Figure 3-9. Door sensor. The door sensor circuit provides a feature to work with a special type of door sensor that is tamper-proof. This prevents an internal security breach, where someone with authorized access to an area could potentially short-out the contacts on the door sensor.
  • Page 17 Chapter 3: Installing the Intelli-Pass Figure 3-11. Jumper settings when used with a normal door sensor. Figure 3-12. Jumper settings when used with an anti-tamper door sensor. If you aren’t using the door sensor, keep the link in place as shown in Figure 3-13. Figure 3-13.
  • Page 18: Fire Panel Integration

    Intelli-Pass Quick Start Guide 3.8. Fire Panel Integration To automatically unlock doors in case of a fire, you can connect units to a fire panel. 1. Once you unlock a door via the fire override inputs, press the reset button on the control unit (see Figure 3-14) to reset the unit manually.
  • Page 19: Alarm Output

    Chapter 3: Installing the Intelli-Pass Figure 3-16 shows the location of the Reset switch. If you are not using the fire panel integration, keep the link in place as shown in Figure 3-17. Figure 3-16. Reset switch. Figure 3-17. Fire panel not used. 3.9 Alarm Output Certain conditions that occur on the unit will cause the Alarm Relay to operate.
  • Page 20 Intelli-Pass Quick Start Guide Figure 3-18. Alarm input relay connected. Figure 3-19. Alarm panel relay not connected. 724-746-5500 | blackbox.com Page 20...
  • Page 21: Wiegand Output (26-Bit Protocol)

    Chapter 3: Installing the Intelli-Pass Or, the Intell-Pass can use the alarm relay to power a third-party buzzer or siren. See Figure 3-20. Figure 3-20. Using the alarm relay to power a third-party buzzer or siren. 3.10 Wiegand Output (26-bit Protocol) The Intelli-Pass controller offers a 26-bit Wiegand output for seamless integration into a third-party access control system.
  • Page 22: Network Connection

    Intelli-Pass Quick Start Guide 3.11 Network Connection If the unit is networked, connect the RJ-45 plug as shown in Figure 3-22. Figure 3-22. Network connection. 3.12 Powering On the Unit 1. Plug the power supply into the power outlet and make sure that the supply is switched on. 2.
  • Page 23: Software Setup

    Chapter 4: Software Setup 4. Software Setup 4.1 Factory Default for Accessing Menus On a new unit, all fingerprint indexes are unused. When you power on a new unit, it will immediately go to the setup menu. The menu consists of a number of options that you can select or turn on/off, and requires you to enter numeric values using the keypad.
  • Page 24 Intelli-Pass Quick Start Guide NOTE: You must also enter this same password into the Management Software, so make a record of the password before enter- ing it. 4. After you enter the 16th digit, the Head Unit will automatically go to the next screen. NOTE: You can’t re-enter the password once to confirm;...
  • Page 25 Chapter 4: Software Setup KEY 1 WHEN READY 8. Once you place the finger on the scanner, make sure that the finger is flat and straight. Then press 1 on the Head Unit keypad. NOTE: Either use a different finger or preferably a different person for the second enrolled finger. After about 4–5 seconds the Head Unit will display: PRINT STORED REMOVE FINGER...
  • Page 26: Entering The Menu After Initial Setup

    Intelli-Pass Quick Start Guide 4.5 Entering the Menu After Initial Setup Other than at initial setup, any enrolled manager can access the menus. 1. If the unit is in finger-only mode, press and hold the # key on the Head Unit for 2 seconds. If the unit is in finger+PIN mode simply press and release the # key.
  • Page 27: Troubleshooting

    • Package it carefully. We recommend that you use the original container. • If you are returning the Intelli-Pass, make sure you include everything you received with it. Before you ship for return or repair, contact Black Box to get a Return Authorization (RA) number. Page 27...
  • Page 28: Appendix A: Head Alignment Template

    Intelli-Pass Quick Start Guide Appendix A. Head Alignment Template 724-746-5500 | blackbox.com Page 28...
  • Page 29: Appendix B: Software Flowcharts

    Appendix B: Software Flowcharts Appendix B. Software Flowcharts Figure B-1. Menu map. Page 29...
  • Page 30 Intelli-Pass Quick Start Guide Figure B-2. User data menu map. 724-746-5500 | blackbox.com Page 30...
  • Page 31 Appendix B: Software Flowcharts Figure B-3. System data menu map. Page 31...
  • Page 32 About Black Box Black Box Network Services is your source for more than 118,000 networking and infrastructure products. You’ll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free, live 24/7 Tech support available in 20 seconds or less.

This manual is also suitable for:

Sac510saSac500msa

Table of Contents