H3C S5560-EI Series Troubleshooting Manual page 49

Hide thumbs Also See for S5560-EI Series:
Table of Contents

Advertisement

Loopback is not set
Media type is twisted pair
Port hardware type is 1000_BASE_T
100Mbps-speed mode, full-duplex mode
Link speed type is autonegotiation, link duplex type is autonegotiation
Flow-control is not enabled
The Maximum Frame Length is 10000
Allow jumbo frame to pass
Broadcast MAX-ratio: 100%
Multicast MAX-ratio: 100%
Unicast MAX-ratio: 100%
PVID: 1
Mdi type: automdix
Port link-type: access
Tagged Vlan:
none
UnTagged Vlan: 1
Port priority: 0
Last link flapping: 0 hours 0 minutes 6 seconds
Last clearing of counters: Never
Peak value of input: 3 bytes/sec, at 2013-01-01 01:59:12
Peak value of output: 0 bytes/sec, at 2013-01-01 00:01:24
Last 300 seconds input:
Last 300 seconds output:
Input (total):
17 packets, 2344 bytes
0 unicasts, 4 broadcasts, 13 multicasts, 0 pauses
Input (normal):
17 packets, - bytes
0 unicasts, 4 broadcasts, 13 multicasts, 0 pauses
Input:
0 input errors, 0 runts, 0 giants, 0 throttles
0 CRC, 0 frame, - overruns, 0 aborts
- ignored, - parity errors
Output (total): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Output (normal): 0 packets, - bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Output: 0 output errors, - underruns, - buffer failures
0 aborts, 0 deferred, 0 collisions, 0 late collisions
0 lost carrier, - no carrier
a.
If the statistics are not zero, the following problems might have occurred:
Inconsistent configuration—Verify that the local and peer ports have the same configuration
(including speed and duplex mode). If they are not the same, modify the configuration of
the local port.
Interface hardware failure—To test such a failure, connect the cable that is connected to the
local port to a correctly operating port (for example, Port A) with the same configurations as
the local port. If Port A forwards traffic correctly, you can determine that the hardware of the
local port fails. In this event, you must replace the local port with a correctly operating port.
Transceiver module, fiber, or twisted pair failure—To test and resolve such a failure, replace
the transceiver module, fiber, or twisted pair with a good one.
b.
If the problem persists, contact H3C Support.
0 packets/sec 3 bytes/sec 0%
0 packets/sec 0 bytes/sec 0%
45

Advertisement

Table of Contents
loading

Table of Contents