What To Do If; The Power Does Not Come On; Initialization Is Not Performed Or Initialization Fails; Vpanel Doesn't Start Correctly - Roland MDX-40A User Manual

Benchtop milling machine
Hide thumbs Also See for MDX-40A:
Table of Contents

Advertisement

5-4 What to Do If...

The Power Does Not Come On.

Has the Emergency Stop button been
pressed?
When the Emergency Stop button is pressed, the
power does not come on. Release the Emergency
Stop button.
 P. 42, "To Cancel an Emergency Stop"

Initialization is Not Performed or Initialization Fails.

Is a front cover open?
When starting the machine, close the front cover. For
safety, initialization is not performed when a cover
remains open at startup.
Is a large amount of cutting waste pres-
ent?
Clean away any cutting waste. Clean the area around
the spindle head especially carefully.
 P. 76, "Maintenance"
Is anything caught on the spindle head or
table?
Check whether something has become caught and
is impeding initialization.

VPanel Doesn't Start Correctly.

Has initialization been completed?
Before you start VPanel, first switch on the power to
the machine.
 P. 43, "Starting and Quitting"
Is the computer connected?
Check whether the connector cable has come
loose.
Is the driver installed correctly?
If the connection to the computer is not made in
the sequence described, the driver may fail to be
installed correctly. VPanel does not function normally
when driver is misconfigured. Check again to ensure
that the connection was made using the correct
procedure.
 P. 38, "Installing the Windows-based Driver"
78
Chapter 5 Appendix
Chapter 5 Appendix
Are two or more machines connected to a
single computer?
VPanel cannot control more than one machine at the
same time. Never connect two or more instances of
this machine to a single computer.

Operations are Ignored.

Is the cable connected?
Connect the cable securely.
 P. 34, "Cable Connections"
Was the machine started according to the
correct procedure?
Simply switching on the main power does not en-
able operation. Start the machine using the correct
procedure.
 P. 43, "Starting and Quitting"
Is a front cover open?
This machine restricts some operations when a front
cover is open. Close the front cover.
Is the VIEW lamp on?
Press and hold the VIEW button to cancel the paused
state.
Is the lamps flashing an error message?
 P. 80, "What to Do If a Flashing Error Is Displayed.""
Is a large amount of cutting waste pres-
ent?
Clean away any cutting waste. Clean the area around
the spindle head especially carefully.
 P. 76, "Maintenance"
Is the driver installed correctly?
If the connection to the computer is not made in
the sequence described, the driver may fail to be
installed correctly. VPanel does not function normally
when driver is misconfigured. Check again to ensure
that the connection was made using the correct
procedure.
 P. 38, "Installing the Windows-based Driver"