Trigger Delay; Trigger Counter; Frame Counter; Trigger Range Limit - Sony XCL-SG510C Technical Manual

Module
Table of Contents

Advertisement

Trigger delay

The camera can delay the trigger signal.
Trigger signal
Exposure
Sensor output
Command
Parameter
TRG-DLY
0 to 4000000

Trigger counter

Accepted triggers by which video output is performed are counted. Triggers are counted up by the internal counter even
in the free-run operation. Setting 0 resets the counter. Triggers that have been removed by trigger range limit are not
counted. The trigger counter returns to 0 when the upper limit (2147483647) is reached.
Command
TRG-CNT

Frame counter

The frame counter increases when an image is output. Setting 0 resets the counter. The trigger counter returns to 0 when
the upper limit (2147483647) is reached.
Command
FRAME-COUNTER

Trigger range limit

Only signals in the set trigger width can be accepted as the trigger signal. This functions as a noise filter, which removes
chattering or disturbance noise in the trigger signal line. This also functions as a trigger selector, whereby only a specific
camera can be operated by the trigger when multiple cameras share one trigger signal line. When the trigger signal is
input, exposure is started after the latency as per trigger range settings. If the trigger width is out of the range, video is
not output. If the trigger source is a soft trigger, trigger range limitation is not enabled.
Command
TRG-RANGE
TRG-RANGE-LOWER
Trigger range operation example
EXP=300, TRG-RANGE-LOWER=100 in the figure.
Trigger signal
Exposure
Sensor output
Setting
Trigger delay [µs]
Parameter
0
Trigger range off
1
Trigger range on
1 to 2000000
Trigger range lower limit [µs]
100 µs