Download Print this page

Vivotek AE-238 Installation Manual page 8

Ae series outdoor housing

Advertisement

AE-238, AE-243
AE-238
DC 12V OUT -
AC 24V OUT -
AC 24V IN
Below is the pinouts for the DI/DO terminal block:
Facing the rear side of the housing, from left to right:
DO2
DI2
RS485+
RS485-
DO+
DI-
DO1
DI1
Ground
to camera
to external IR
Tank water pump control, connects to IP camera's DO for manually triggering
washer.
Wiper control.
RS485+, RS485 can be used to control IR illuminator beam angles, etc.
RS485-
+5V VCC
GND
IR LED status
IR control, synchronizes day/night mode switching for IP camera. It is related to IR
cut filter.
AE-243
for IR LED
AC 24V OUT -
AC 24V IN
8