Installation And Maintenance Planning - Agilent Technologies 8712ET User Manual

Option 100 fault location and structural return loss measurements rf network analyzers
Hide thumbs Also See for 8712ET:
Table of Contents

Advertisement

Table 7-1
Characteristic
Cable attenuation at 900 MHz (dB/100 ft.)
Characteristic impedance
Velocity factor
Table 7-2
Characteristic
Insertion loss
Cable attenuation (dB/100 ft.)
System return loss (dB)
Cable length (ft.)
Connector loss (fault loc., dB)
Table 7-3
Characteristic
System return loss (dB)
Connector loss (fault loc., dB)
Characterizing and Verifying Antenna Systems

Installation and Maintenance Planning

Installation and Maintenance Planning
Installation and maintenance planning is used to verify the performance
of the antenna system. The following tables can be used to enter test
results along with the specified limits and pass/fail margins. This allows
for quick monitoring and recording of the antenna system's performance.
Incoming Inspection
Installation
Maintenance
7-10
Limit/Spec
Test Result
Limit/Spec
Test Result
Pass/Fail
Test Result
Margin
Option 100 Fault Location and SRL
Date/Time
Date/Time
Date/Time

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8712es8714et8714es

Table of Contents