Step 6: After setting the CAN and COM port parameter, press the "Next" button to
start to set their Modbus devices parameters. Users can use the add button, erase
button, update button or delete button to modify their Modbus devices parameters.
And users can view the information of devices, application object and assembly object
by clicking these "View" buttons.
Step 7: After the configuration of Modbus devices parameters, press the "Next" button
and start to build the specific EDS file for the I-7242D. Set the EDS file information and
give it a description in the description box. Then set the poll, strobe-bit and COS/Cyclic
I/O connection path for the I-7242D.
I-724D DNS/Modbus RTU Quick Start User Guide, July 2006, Version 1.1 ------ 6