In system CD-2502 there is a possibility of individual settings of some parameters of entry phone connected with
uniphone calling and functions of combination lock. Values of parameters 1-3 may be changed by occupants by user's
menu (see page. 43), parameters 4-6 are available for the installing specialist only.
Starting the program of individual settings for the selected apartment (in example No. 12)
Parameter values are changed by means of keys 1 - 6. Each pressing of the selected button results in setting of next
value of the parameter. Keys 7 and 9 are used for switching of the parameter edition mode – the previous and next
apartment number.
Calling tone
Parameter can take values from the range 0...7. Parameter value is defined by one of 8 pre-defined calling tones.
Entry phone enables setting three volume levels and calling of increasinng volume (requires setting at least three
bells)
C — silent bell
U — moderate bell
G — loud bell
N — increasing bell
Entry phone allows defining the number of bells which will be generated after calling. From 1 to 8 bells can be set.
If needed entry phone reaction after calling can be changed:
- - Uniphone switched off. Selection of this option makes that it is impossible to make a connection with the
apartment for which such setting was selected. An attempt to make a connection will be followed by a message
OFF .
NOTE! If local number is in the range of serviced number and parameter LdP in procedure P-1 is set up, than
dial the uniphone which is switched off will cause the call forward.
d - Uniphone functions as a bell. Uniphone may be called, however, conversation cannot be conducted and
electro-catch cannot be controlled
A - Active uniphone. Uniphone may be called, conversation can be conducted and electro-catch may be
controlled.
P - Active uniphone. Uniphone may be called, conversation can be conducted and electro-catch may be
controlled. There is no confirmation of use of lock code and electronic keys.
b - Active uniphone. Uniphone may be called, conversation can be conducted and electro-catch may be
controlled. During connection the camera in external panel is turn off - blockade of vision.
NOTE! JP1 jumper that control the supply of camera in the panel must be set to supply in accordance with
the setting parameter CAon (previously named EUC).
P-5 Individual settings
5
Calling volume
Calling options
Number of bells
1
3
2
Keys used for changing individual settings
Parameter No. 1. Calling tone, key 1
Parameter No. 2. Calling volume, key 2
Parameter nr. 3. Number of bells, key 3
Parameter No. 4. Calling options, key 4