The procedure facilitates the activation of an entry phone system. Starting procedure P3 enables the installing
specialist to check the correctness of functioning of uniphones mounted in apartments without any help of other
persons. Activation of CD-2502 was described in chapter 6.8, on page 24.
3
P-3-0
ON/OFF
Switching on/switching off of installation procedure. During activating the procedure their
limit time should be entered - from 1 minute to 255 minutes (4h15m).
P-3-1
FLO
low range of searched numbers
P-3-2
FHi
high range of searched numbers
P-3-3
Searching for the picked up (incorrectly placed) receiver. When this procedure is started,
searching for picked up (incorrectly placed) receivers begins. On the display numbers of
successively checked apartments are being indicated. When uniphone with the picked up
(incorrectly placed) receiver is found in one of such apartments, then the display of the
external panel will show the number of such uniphone for a couple of seconds. In order to
start searching for next uniphones, a key with a KEY symbol should be pushed or one must
wait a couple of seconds. After that searching will be started automatically.
P-3-4
LOC/OFF
Blocking the possibility of using an entry phone. In this mode it is not possible to get
connection with any apartment, however, entering any number from a keyboard of an entry
phone will result in unblocking the entrance. This function can be used during the activation
of an entry phone and enables the occupants to enter the staircase with a door equipped
with self closing device.
P-3-5
L-F
Calculator converting uniphone logical number to its physical number. Calculator functions
on condition that range shift parameter has been set or the exchange has been set to hotel
numbering mode. In order to calculate the physical number of a uniphone, its logical number
should be entered from a keyboard and then it should be confirmed by a key with a symbol
of key.
P-3-6
F-L
Calculator converting the physical number to logical number. The principle of operation is
similar to procedure P-3-5. In order to calculate the logical number of a uniphone, its physical
number should be entered from a keyboard and then it should be confirmed by a key with
a symbol of key.
P-3-7
SYS
Restoring the default parameters of the exchange operation (defined by procedures P-1 and
P-2).
P-3-8
CoL
Restoring the default parameters of the values of the coded lock. Restoring the codes of
a combination lock results in restoring the default code of an installing specialist.
P-3-9
OPL
Restoring the default values of individual settings in electronic cassette.